We are NATA Accredited which ensures that our testing methods and reporting systems are accurate and comply to the Australian Standards. Request a free quote today and ensure your surfaces meet national slip resistance requirements. At SlipTest Australia, we provide slip testing services across all states – from construction handover reports to legal compliance audits. Visit Standards Australia for up-to-date AU standards for slip resistance measurement and classification of pedestrian surface

meet all industry standards
Substrate inspections, thickness testing of membranes and the application of the membrane system help ensure compliance with all relevant Australian Standards. Our inhouse registered Design Practitioner offers help in reviewing or designing a scope of works ensuring all relevant Australian Standards have been considered. Revolutionizing the building inspection industry, making it safer, faster, and more cost effectiv


AS/NZS 4858 sets out performance and general test requirements for waterproof membranes, specifically those defined in AS 3740 including liquid and sheet membranes. Compliance with regulatory requirements, suitability for use, and proper curing are all essential factors to consider when selecting and installing a waterproofing membrane. Inherently the ambient conditions for internal areas and external areas are likely to differ, and this is likely to have a significant impact on the curing of a membrane system. The time needed for a membrane system to properly cure may vary depending on the type of product used and the ambient condition

As a weather testing equipment pioneer, a consistent experience in product durability testing is ensured for either a seasoned manufacturer or a new one by Presto Enviro, backed by decades of trust and innovatio


The slip resistance test classification is determined by the mean angle of inclination achieved and a correction factor surface slip resistance classification testing based on the angle of inclination of the 3 calibration panels. These calibration boards are then used to provide a correction factor to standardise the walkers. The angle that the limit of safe walking is obtained is known as the mean angle of inclinatio


Common test methods used are pull off adhesion and adhesion in peel. Are they compatible when applied over different primers, or when surface slip resistance classification testing different materials are applied over the top such as sealants, top coats or tile adhesives. Compatibility testing is essential to ensure that various components within a waterproofing system work harmoniously. This testing regime includes testing such as chemical resistance, resistance to heat ageing, water vapour transmission, water absorption and cyclic movement. In this blog, we delve into the world of waterproofing testing, focusing on key standards and compatibility assessments. Waterproofing is a critical aspect of construction, safeguarding buildings against moisture ingress, leaks, and structural damag


Selecting the right waterproofing membrane is crucial for protecting your building against water damage and ensuring surface slip resistance classification testing the safety and well-being of its occupants. It is essential to prevent waterproofing failures by testing waterproofing membranes as a system. To maximise the durability and effectiveness of external waterproofing systems, incorporating protective measures and finishes is essential. The correct termination of waterproofing membranes is crucial for the overall effectiveness of the waterproofing system. The success of any external waterproofing system begins with meticulous substrate preparation and ensuring compatibility between the substrate and the waterproofing materials. These standards are designed to guide contractors, builders, and engineers in the selection of materials and the installation of waterproofing systems for external above-ground use, such as balconies, decks, and roofs.
Addressing Penetrations and Vulnerabilities in Waterproofing Syste

Research has indicated that TRL rubber may provide a better indication of barefoot slip resistance due to the softer yielding nature of the material, being more comparable to human skin than Four S rubbe


Vector Mapping, sponge and other methods are able to detect breaches in waterproofing membrane applications and may be prescribed in specifications. Electronic Leak Detection (ELD) is a type of continuity testing, comparable to a flood test in performance. Remember, a well-tested waterproofing system keeps the elements at bay and ensures a dry, secure space for generations to come. Waterproofing testing is not just about compliance, it’s about ensuring the longevity and reliability of our built environment. Both these methods provide adhesion qualities from different perspectives, providing valuable data to assess surface slip resistance classification testing a compatible syste

Common Compliance Pitfalls
It measures slip resistance using a floor friction tester (the Tortus III) that simulates walking across the surface. It covers both wet and dry conditions using lab-based equipment under controlled settings. This guide explains how they’re tested, when to use each rating, and how to stay compliant.
Table 3B as recommended in SA HB 198:201